Description
1.1Typical Application
- Meter (water/gas/electricity etc.) reading
- Digital transformation of traditional instruments
- Object presence detection
- Posture Detection
- Optical Character Recognition Smart Pen and Smart Light
- QR code reading
1.2Meter Reader High Level Design
The mVMR1108 makes it easy to develop a variety of meter reader products. The following diagram shows the main components that make up a meter reader.
1.3Example of a gauge
Example of water representation
Example of numeric representation Example of pointer representation
1.4Product Specification
1.4.1Technical Specification
Diagnostic Property | Details | Remark |
PCB Size | 45(W) x 30(H) x 6.8(T) mm | T-shaped |
Camera Size | 9(W) x 12(H) x 5.6(T) mm | |
Operating Voltage | 2.8 to 3.6 V | |
Operating Temperature | -20 to 50°C | |
Operating Humidity | 0 to 95% RH | non-condensing |
Optical Range | visible light | mVMR will automatically flash when taking photos |
LED | 2 x SMD0805 LEDs | Infrared or white light, < 20mA |
Communication Interface* | TTL/UART, Compatible with AT commands | Default 115200/8/N/1 |
*TTL/UART serial port can be directly connected to the microcontroller, if you need to connect to the computer (USB or serial port), please use the appropriate adapter according to the actual physical interface (eg: ‘USB to TTL’ or ‘TTL to RS232″)
1.4.2Wiring Definitions
No. | Pinout | Desc. |
1 | RX | TTL RX |
2 | TX | TTL TX |
3 | 3.3V | DC3.3V Input |
4 | GND | 地 |
Note: Pin spacing is 2.0mm with a 90° pin connector unless otherwise noted.
1.4.3Current Consumption
The current consumption in different operating modes is shown in the table below.
Operating Mode | Mini. Value | Typical Value | Max. Value | Unit |
Hibernation | 13 | 27 | 35 | uA |
Initialisation and readiness | 16 | mA | ||
Meter reading | 19 | 52 | 65 | mA |
Executing other AT commands | 20 | mA |